Polarization Extinction Ratio Meter View larger

Polarization Extinction Ratio Meter

Reference: GPC-ERM-202

The ERM-202 is a dual channel polarization extinction ratio (PER) meter specifically designed to simultaneously measure the PER and power ratio of a device with two polarization maintaining (PM) outputs, such as a Y-branch fiber gyro IOC, PM coupler (PMC), or polarization beam splitter (PBS), as well as evaluate the performance (output DOP) of depolarizers.






Alexandre Besson
Business Unit Director
+33 5 57 10 92 84
a.besson@laser2000.fr
Product request: Polarization Extinction Ratio MeterX



Dear Besson,

I am interested in the following product: Polarization Extinction Ratio Meter


I am interested in:

an offer
Information material
a call back and consulting
Please complete at least the mandatory fields marked with *.



* Title:

Academic Degree:

First Name:

* Last Name: * Last Name:

* Company Name: * Company Name:

Company Address:

* Street: * Street:

* Zip Code: * Zip Code:

* City: * City:


* E-Mail: * E-Mail:

* Phone: * Phone:

Text:




* What do you see in picture 2?* What do you see in Picture 2?

laserdiode laserschutzbrille laserschutzfenster leistungsmessgerät


Bitte auswählen:Please select:    Diode    Gauge    Safety Goggles    Safety Windows   



Please check red marked fields.




Your request has been sent successfully. You will be contacted as soon as possible.



Alexandre_Besson.jpg


Product description

PER Meter by General Photonics

The PER Meter ERM-202 is a dual channel instrument for measuring the Polarization Extinction Ratio (Polarization Extinction Ratio PER). The second input can be PER and measuring the optical power level on components with two PM outputs in parallel. The PER Meter ERM-202 is therefore very well suited for integrated optical chips (IOC) with Y-coupler as used in fiber gyroscopes, PM coupler (PMC) and polarization beam splitter (PBC / S).

Optionally, a single-channel solution is available which can be retrofitted to 2 channels.

For each channel of the ERM-202 there is an analogue output which provides the PER measurement signal as voltage level provides. This allows the design of a control loop to automate the alignment of PM fibers.

The PER Meter ERM-202 is characterized by its large PER dynamic range of 50 dB, an angular resolution of 0.06 ° and its brilliant and high-contrast OLED display.

The instrument has 4 measuring speeds from 0.1 to 1 s / measuring cycle. PM fiber can be in the fast Align measurement mode in real time. For very accurate measurement results, the measurement time can be extended. PER, axis angle, Power level and power quotient are automatically measured and displayed in parallel on the OLED.

The PER Meter ERM-202 is an optimal solution for aligning PM fiber pigtails especially in PM fiber pigtail assembly on optical modulators, PM waveguide structures, laser diodes, fiber optic PM components such as PM coupler and beam splitter, PM fiber plug assembly, characterization of depolarizers, alignment of PM fibers before splicing, production of PM fiber coils and fiber gyroscopes.

Properties of PER Meter

  • Two measuring inputs
  • Simultaneous measurement of the PER and measurement of the power ratio
  • PER measuring range> 50 dB
  • High Contrast OLED Display
  • High angular resolution

PER Meter Applications

  • IOC PER and measuring the coupler division ratio
  • PMC and PBS PER and measurement of the coupler division ratio
  • Laser diode PM fiber pigtailing
  • PM patch cord assembly
  • Align PM fibers before splicing
  • Quality assurance in the production of PM fiber coils and fiber gyroscopes

PER Meter Specifications

Wavelength Range

1260 to 1650 nm

Calibrated Wavelengths2

1550 and 1310 nm

PER Dynamic Range

>50 dB

PER Measuring Ranges3

0 ~ 50 dB for Input Power from -5 to 10 dBm 

0 ~ 30 dB for Input Power from -25 to -5 dBm

PER Resolution

0.1 dB

PER Accuracy

± 0.15 dB for ER <30 dB

Angular Resolution

0.06 °

Angular Accuracy

± 1 °

Performance Measurement Accuracy

± 0.5 dB

Resolution of the Power Measurement

0.02 dBm (PER < 30 dB) 

0.2 dBm (PER > 30 dB)

Input Power Measuring Range

-30 dBm to 10 dBm

Measurement Speed

0.1, 0.2, 0.4, 1 s/Polariserrotationszyklus

One Channel Version also has a 10s Measurement Cycle and a Manual Polarizer Control Mode

Connectors

Free space Adapter for FC Plug

Max. Optical Input Power

300 mW

Operating Temperature Range

0 bis 40° C

Storage Temperature Range

-20° C bis 60° C

Display

OLED Display

Interfaces

 

USB, RS-232, Ethernet, GPIB

Analoger Ausgang

0 - 5V PER analog Output Voltage for each Channel

Power Supply

100-240 V AC, 50-60 Hz

Dimensions

2U 19" half rack width, 14"(L) x 8.5"(W) x 3.5"(H)

Annotation:

1 Other wavelengths and plug adapters on request

2 Other calibrated wavelengths on request

3 For measurements at or slower than 0.4s / cycle

30 other products in category Optical Test Equipment